Energy

Independent loss analysis for PV farms

Our demo on public data found one inverter idle for 132 days: at least 2,246 PLN (assumed 450 PLN/MWh). We count it for your farm.

For asset managers, O&M heads and finance directors at companies with PV farms.

Book a free intro auditSee the 5.05 MWh loss in the demo

The Helio demo: a real loss of 5.05 MWh and 2,272 PLN, the simulated curtailment shown apart and the table of losses by cause
The Helio demo on the data of a real installation: real losses apart, the simulation always marked.
Why now

Three problems with public numbers

14.2%

The grid operator curtails outputIn June 2026 PSE, the grid operator, curtailed 14.2% of the potential output of large PV farms (246.9 GWh).

  • Jan–Sep 20261,736.9 GWh
  • All of 20251,376 GWh
Renewable energy curtailed by PSE, Forum Energii data.
Source: Forum Energii, Monthly Magazine, September 2026 (opens in a new tab), gramwzielone.pl, 9 July 2026 (in Polish) (opens in a new tab), gramwzielone.pl, 29 July 2026 (in Polish) (opens in a new tab)
31 Oct 2026

A new data dutyA generator with a type B, C or D module sends the operator structural, real-time and schedule data (art. 9j para. 1a).

Fine
1,000 to 500,000 PLN, one per quarter
Grid measure
the module halted for up to 24 hours
Source: Journal of Laws (Dz.U.) 2026, item 1348, art. 9j para. 1a, art. 9je, art. 56 para. 1 point 19a and art. 16 (in Polish) (opens in a new tab)
5.08%

Average power loss of US PV sitesThe 2025 average from inspections (a sample of 373 GW).

Source: Raptor Maps (a company that sells inspections), 2026 Global Solar Report, via pv magazine USA, 25 February 2026 (opens in a new tab)
Who it is for

What an asset manager, an O&M head and a finance director get

Asset manager
A report where every number has its own query.See what you get
O&M head
A dated list of problems: which inverter went down and when.See what you send and what comes back
Finance director
The loss in PLN, with the energy price, source and method beside it.See the numbers and their method
What we do

What you get

Data analysis and report
Losses in MWh and PLN by cause, problems with dates.
Operational dashboard
A separate dashboard for your farm only, in Polish and English.
Questions to your data in your own words
The AI reads your database in read-only mode (an MCP server). It computes nothing, it describes query results.
Custom tools and integrations
Zabbix, SCADA exports, inverter portals.
Deployment on your side or in a private instance
Under a data processing agreement, with a login, backups, documentation and training.
Support and development
Data refresh, security fixes, dashboard development.
Proof

A demo on real data, with the method next to every number

2015: inverter inv4 is down from 22 April to the end of its data on 1 September, 132 days. The other seven inverters run all year.

Helio, our own project: 8 inverters, 2015. Real losses of 5.05 MWh (at least 2,272 PLN at an assumed 450 PLN/MWh), 98.8% of them from this one outage.
  • Alerts that hit a real fault9 of 9
  • Real faults the detector found6 of 31
The detector on the FHC set with labelled faults. Samples: 9 windows and 31 runs; the method and sources are under “Details”.

Demo in PolishDemo in English

How it works

A pilot on one farm in three steps

  1. You send the data

    A CSV from your SCADA or inverter portal, or a read-only Zabbix token.

  2. We count

    Each inverter compared with the others on the same farm.

  3. We return the results

    Losses in MWh and PLN, dated problems, a dashboard for your farm.

What we need

  • AC power of each inverter
  • A reading every 5 minutes or less
  • At least 4 inverters
  • A year or a quarter of data

Detection scope

Accuracy on your farm
We measured it on one lab installation.
Faults of an hour or longer
The detector looks for lost energy, so it skips shorter disturbances.
A 15% threshold below the others
An inverter with a smaller drop counts as healthy.
Data and security

A file export needs no access to your systems

A file, not access
You send a file without names or contact details of people.
NDA first
Yours or ours, covering one analysis.
Deleted after the pilot
30 days after the final report, with a deletion note.
AI only with consent
Written consent for a named AI provider, which you can withdraw.
What stays yours
Your data and your configuration.
Packages and prices

Packages, prices in PLN, net

The intro audit is free and ends with a fixed price in writing; the paid step is the analysis of your export.

Energy data-analysis packages with net prices in PLN
PackagePrice (net)What it covers
Intro auditfreeA call of 30 to 45 minutes on your data and goals. We assess the file format and give a fixed price for the data analysis.
Data analysis and report8,500 PLNA report in Polish: losses in MWh and PLN by cause, a dated list of problems, a note on data quality and a walk-through. The price is for a standard file; an unusual format is quoted separately.
Pilot dashboard15,000 PLNA private dashboard for one farm, in Polish and English, with the list of losses and problems. Two rounds of changes. Files for your hosting, or a demonstration in a meeting.
Production deployment13,000 PLNScheduled data pulls, automatic refresh of the analysis, a login, backups, documentation and one hour of training, on your side or in a private instance under a data processing agreement.
Support and developmentfrom 1,500 PLN a monthWatching that the data keeps refreshing, security fixes, a monthly review of the report and development hours.
AI analysis over an MCP server5,500 PLN plus 500 PLN per report, plus the AI provider's costSetting up a read-only MCP server on your data, or AI reports that we run. Needs your written consent for the AI provider.
Details

Full wording, method and sources

Curtailment by the grid operator

Forum Energii calculated that in June 2026 PSE, the grid operator, curtailed 14.2% of the potential output of large PV farms (246.9 GWh). From January to September 2026 it curtailed 1,736.9 GWh of renewable energy in total, more than in all of 2025 (1,376 GWh). Sources: Forum Energii, Monthly Magazine, September 2026 (opens in a new tab), gramwzielone.pl, 9 July 2026 (in Polish) (opens in a new tab), gramwzielone.pl, 29 July 2026 (in Polish) (opens in a new tab).

The data duty in its new wording

The act of 18 September 2026 amends art. 9j: a generator with a type B, C or D module sends the operator structural and real-time data, and sends and carries out schedule data (para. 1a). The change applies from 31 October 2026 (art. 16). Art. 9je is a grid measure, not a fine: for a gross breach of the requirements on schedule data, real-time data or the operator's orders, the operator may, on the terms set in the network operation manual, restrict or halt the module's operation for no longer than 24 hours, with no compensation. The money fine is in art. 56 para. 1 point 19a: it covers failing the duties of art. 9j para. 1a, structural data included, runs from 1,000 PLN to 500,000 PLN and is one fine for all breaches in a calendar quarter (art. 56 para. 3 point 3 and para. 3d). Source: Journal of Laws (Dz.U.) 2026, item 1348 (in Polish) (opens in a new tab).

Power losses at PV plants: an average from inspections

The average power loss in 2025 across PV sites in the US (a sample of 373 GW) was 5.08%. Inverters account for less than a quarter of equipment losses; strings, combiner boxes and trackers cause most of the rest. This is US data. Source: Raptor Maps (a company that sells inspections), 2026 Global Solar Report, via pv magazine USA, 25 February 2026 (opens in a new tab).

The demo: data, method and accuracy

Helio is our own project, not a client deployment. The demo runs on two public datasets, and the simulation is always marked. 5.05 MWh of real losses in 2015, at least 2,272 PLN at an assumed price of 450 PLN/MWh. Source: one installation from the public NREL PVDAQ dataset (system 1204, a 78.6 kWp rooftop, 8 inverters with data, readings every 5 minutes). It is a lower bound: the data of inverter inv4 ends on 1 September 2015, while the outage was still on. 98.8% of that loss is one outage: inverter inv4 was down for 132 days, from 22 April 2015 to the end of its data. 9 of 9 detector windows overlap a labelled fault run (95% Wilson confidence interval: 70% to 100%). Test set: the FHC twin plants, 4 strings, readings every 30 seconds over 25 days within 17 June to 15 July 2025. The detector found 6 of 31 labelled fault runs, including 6 of 8 where the sun was up for at least an hour. Most of the rest are sensor errors and disturbances shorter than an hour: the detector looks for lost energy, so by design it does not catch them. The FHC set is single 400 W modules, so the result does not carry over to another farm. The price of 450 PLN/MWh is an assumption, not a market quote. The samples are small (9 windows and 31 runs). Both datasets are CC BY 4.0. Data: Deline et al. (2021), PVDAQ, NREL/OEDI, doi:10.25984/1846021 (opens in a new tab), Bradl et al. (2026), Zenodo, doi:10.5281/zenodo.18979877 (opens in a new tab).

File requirements and Zabbix

An export of your inverter data: a CSV from your SCADA or the inverter portal, for a year or a quarter. We need the AC power of each inverter with a timestamp every 5 minutes or less, and at least four inverters. Instead of a file you can give a read-only token for your Zabbix. By default Zabbix keeps 31 days of history, so a year or a quarter needs the export or a longer history setting. We compare each inverter with the others on the same farm and check the result on your data. We measured detection accuracy on one lab installation, and the result does not carry over to another farm. The detector looks for lost energy, so by design it does not catch short disturbances and sensor errors. An inverter that delivers less than 15% below the others counts as healthy.

AI analysis and deployment

From an export of your inverter data we count the energy lost, in MWh and PLN, by cause, and list the problems with dates. Next to every number in the report stands the query that counted it, so you can check it. In the AI analysis you ask about your data in your own words, and the AI reaches your database through a server that can only read. Every query is logged, and limits on rows and time protect the database. The AI computes nothing: it describes the results of queries. We switch this on only with your written consent for a named AI provider. The dashboard and the analysis run on your infrastructure or in a private instance set up for you, under a data processing agreement that names the hosting provider. Data refreshes on a schedule, and you get a login, backups, documentation and training. In support we watch that the data keeps refreshing, install security fixes and develop the dashboard to fit what you need. Integrations: Zabbix, SCADA exports, inverter portals; we join what you already use and fit the tools to your system.

Data and confidentiality

An export of your inverter data needs no access to your systems from us: you send a file. Remove the names and contact details of people from the file before you send it. If you prefer, you give a read-only Zabbix token for the hosts you choose, instead of a file. Before you send the file, we sign a non-disclosure agreement, yours or ours. It covers one thing: one analysis of your inverter data. We delete your data 30 days after we deliver the final report. You get a deletion note with the date and the scope. Your data reaches an AI provider only with your written consent. The consent names the provider, the product, the files and the provider's retention terms, and you can withdraw it. Your data and your configuration (names of sites, thresholds, energy price) stay yours.

Contact

Write to us, we book a free intro audit

  • We reply within 48 hours of your message; a deadline on a weekend or public holiday moves to the next working day.
  • The first step is free: the intro audit, a call of 30 to 45 minutes on your data and goals. After it you get a fixed price in writing.

Or write: contact@tenzanlogic.com

Three fields are required: name, email and a description of the problem.

Three questions that make the quote accurate. Optional.
What the problem is about
What you have today
Horizon

The form data is used only to answer your enquiry. Details in the privacy notice.